Oracle 10 参数配置详解
发布时间:2023-03-11 12:35:52 所属栏目:教程 来源:
导读:semsys:seminfo_semmni
Description
Maximum number of semaphore identifiers.
Data Type
Signed integer
Default
10
Range
1 to 65,535
Dynamic?
No
Validation
Compared to SEMA_INDEX_MAX
Description
Maximum number of semaphore identifiers.
Data Type
Signed integer
Default
10
Range
1 to 65,535
Dynamic?
No
Validation
Compared to SEMA_INDEX_MAX
semsys:seminfo_semmni Description Maximum number of semaphore identifiers. Data Type Signed integer Default 10 Range 1 to 65,535 Dynamic? No Validation Compared to SEMA_INDEX_MAX (currently 65,535) and reset to that value if larger. A warning message is written to the console and or system messages file. When to Change When the default number of sets is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when an attempt is made to create more sets than are currently configured. The application sees a return code of ENOSPC from a semget(2) call. Commitment Level Unstable semsys:seminfo_semmns Description Maximum number of System V semaphores on the system. Data Type Signed integer Default 60 Range 1 to MAXINT Dynamic? No Validation The amount of space that Could possibly be consumed by the semaphores and their supporting data structures is compared to 25% of the kernel memory available at the time the module is first loaded. If the memory threshold is exceeded, the module refuses to load and the semaphore facility is not available. When to Change When the default number of semaphores is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when an attempt is made to create more semaphores than are currently configured. The application sees a return code of ENOSPC from a semget(2) call. Commitment Level Unstable semsys:seminfo_semvmx Description Maximum value a semaphore can be set to. Data Type Unsigned short Default 32,767 Range 1 to 65,535 Dynamic? No Validation None When to Change When the default value is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when the maximum value is exceeded. The application sees a return code of ERANGE from a semop(2) call. Commitment Level Unstable semsys:seminfo_semmsl Description Maximum number of System V semaphores per semaphore identifier. Data Type Signed integer Default 25 Range 1 to MAXINT Dynamic? No Validation The amount of space that Could possibly be consumed by the semaphores and their supporting data structures is compared to 25% of the kernel memory available at the time the module is first loaded. If the memory threshold is exceeded, the module refuses to load and the semaphore facility is not available. When to Change When the default value is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when an attempt is made to create more semaphores in a set than are currently configured. The application sees a return code of EINVAL from a semget(2) call. Commitment Level Unstable semsys:seminfo_semopm Description Maximum number of System V semaphore operations per semop(2) call. This parameter refers to the number of sembufs in the sops array that is provided to the semop() system call. Data Type Signed integer Default 10 Range 1 to MAXINT Dynamic? No Validation The amount of space that Could possibly be consumed by the semaphores and their supporting data structures is compared to 25% of the kernel memory available at the time the module is first loaded. If the memory threshold is exceeded, the module refuses to load and the semaphore facility is not available. When to Change When the default value is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when an attempt is made to perform more semaphore operations in a single semop call than are currently allowed. The application sees a return code of E2BIG from a semop() call. Commitment Level Unstable semsys:seminfo_semmnu Description Total number of undo structures supported by the System V semaphore system. Data Type Signed integer Default 30 Range 1 to MAXINT Dynamic? No Validation The amount of space that Could possibly be consumed by the semaphores and their supporting data structures is compared to 25% of the kernel memory available at the time the module is first loaded. If the memory threshold is exceeded, the module refuses to load and the semaphore facility is not available. When to Change When the default value is not enough. Generally changed at the recommendation of software vendors. No error message is displayed when an attempt is made to perform more undo operations than are currently configured. The application sees a return value of ENOSPC from a semop(2) call when the system runs out of undo structures. Commitment Level Unstable Changes From PrevIoUs Release For information, see semsys:seminfo_semmnu. semsys:seminfo_semume Description Maximum number of System V semaphore undo structures that can be used by any one process. Data Type Signed integer Default 10 Range 1 to MAXINT Dynamic? No Validation The amount of space that Could possibly be consumed by the semaphores and their supporting data structures is compared to 25% of the kernel memory available at the time the module is first loaded. If the memory threshold is exceeded, the module refuses to load and the semaphore facility is not available. When to Change When the default value is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when an attempt is made to perform more undo operations than are currently configured. The application sees a return code of EINVAL from a semop(2) call. Commitment Level Unstable semsys:seminfo_semaem Description Maximum value that a semaphore's value in an undo structure can be set to. Data Type Unsigned short Default 16,384 Range 1 to 65,535 Dynamic? No Validation None When to Change When the default value is not enough. Generally changed at the recommendation of software vendors. No error messages are displayed when an attempt is made to perform more undo operations than are currently configured. The application sees a return code of EINVAL from a semop(2) call. Commitment Level Unstable (编辑:汽车网) 【声明】本站内容均来自网络,其相关言论仅代表作者个人观点,不代表本站立场。若无意侵犯到您的权利,请及时与联系站长删除相关内容! |
推荐文章
站长推荐